ÄúÏÖÔÚµÄλÖãºÉϺ£É½ºÏº£ÈÚÉÌóÓÐÏÞ¹«Ë¾---½ø¿Ú²úƷרҳ---Î÷°àÑÀLIFASAµçÈÝÆ÷¡¢µç¿¹Æ÷¡¢¿ØÖÆÆ÷µÈ²úÆ·

Ô­FMDϵÁвúÆ·ÒÑÉý¼¶»»´úΪFMLϵÁУ¬¹úÄÚ³£ÓõÄÔ­FMD4050µÄÌæ´úÐͺÅΪFML4460£¬±¾¹«Ë¾³£±¸FML4460ÏÖ»õ£¬»¶Ó­ÓиòúÆ·ÐèÇóµÄ¿Í»§ËæʱÓëÎÒÃÇÁªÏµ¡£Í¬Ò»²úÆ·ÊÊÓÃÓÚ²»Í¬µçѹµÈ¼¶£¬Îª¿Í»§Ìṩ¸ü¶à±ãÀû£»²úÆ·³ß´çÓëÔ­À´Ïàͬ£¬±ãÓÚÓû§Ì滻ԭʹÓòúÆ·£¬ÖØÁ¿±ÈÔ­À´²úÆ·ÓÐËùϽµ£»²úÆ·ÑÕÉ«ÓÉÔ­À´µÄÀ¶É«¸Ä±äΪ»Ò°×É«£¨RAL7035£©£¬Ïêϸ²úÆ·×ÊÁÏÇëµã»÷ÕâÀïä¯ÀÀ»òÀ´ÐÅÀ´µç×Éѯ¡£µã»÷ÏÂÔزúÆ·Ñù±¾

Automatic Capacitor Banks
Description
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage installations.
These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cables of adequate cross section, and to supply the
operation signal from a suitable current transformer.

General CharaCteristiCs
LIFASA automatic capacitor banks are composed of the following elements:
High rupturing capacity (HRC) fuses connected to a busbar system.
Contactors specially adapted to the work with capacitors.
Inrush current limiting inductances.
Fast discharge resistors.
Low losses power capacitors.
Reactive power controllers.
Terminals for neutral and ground conductors.
Metal cabinet containing all the switchgear.

Advantages
Equipments wired and tested at works, full finished and supplied with all control and safety devices.
Easy transportation and installation due to their light weigh.
Easy selection of the most appropriate cos ¦Õ to avoid penalty charges on tariffs.
Long life and high reliability, thank to the use of selfhealing and low losses capacitors.
Wide range of power (from 5 to 1600 kvar, 440 V) with standard equipments for immediate delivery.
Option of including various accessories.

Technical characteristics


Rated voltages

230 / 440 /690 V

Rated frequency

50 Hz - 60 Hz

Rated power

5 ... 1600 kvar

Dielectric losses

< 0.2 W/kvar

Capacitors losses

< 0.5 W/kvar

Maximum overvoltage

1.1 Un (8h/dia/day)

Maximum overcurrent

1.3 In

Fast discharge resistors

On each contactor

Regulation equipment Reguladores

MCE ADV or Master controller

Working programs

1:1:1:1 / 1:2:2:2 / 1:2:4:4 /1:2:4:8 / 1:1:2:2 / ¡­

Control voltage

230 V

External current transformer

... /5 (Opcional/Optional)

Temperature range

-25oC/+45 oC max. temp.

Degree of protection

Standars

, , ,

SpeCial equipMent
On request, automatic capacitor banks can be produced to customers special requirements. Among the different possibilities are the following:
Other voltages and frequencies.
Capacitor banks with different degrees of protection.
Capacitor banks for outdoor installation.
Working program 1:2:4:4:, 1:2:4:8:,1:1:2:2:.
Fixed step (for transformer compensation).
Higher powers than the above stated.

BATM 5-180 kvar WALL MOUNTED AUTOMATIC CAPACITOR BANK

DesCription

LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cables of adequate cross section, and to supply the operation signal from suitable current transformer. Wall mounting equipment. POLIMET capacitors.

TeChniCal CharaCteristiCs

Tensi¨®n nominal/Rated voltages......................440 V 50 Hz - 60 Hz
Regulador/Controller ........................................MCE ADV
Programa de trabajo/Working program .........5 opciones
5 options
Condensadores/Capacitors .............................POLB 440 V
Protecci¨®n/Protecci¨®n steps .............................Magnetot¨¦rmico / MCB
Grado protecci¨®n/Degree of protection ......
Color/Colour .......................................................RAL 7035
Entrada cables/Cables entry ..........................Inferior/bottom
Instalaci¨®n/Installation ......................................Interior/Indoor
Montaje/Assembly .............................................Mural/Wall mounting
Tensi¨®n aux. 230V/Aux. voltage 230V .......Autotrafo/ Autotransformer
Interruptor autom./Circuit breaker .................Hasta/Up Qn=40 kvar (...I)
TI externo/External TI ....................................... .../5A (no incl./not included)
a ccesorios /a CCessories
Interruptor general autom¨¢tico o de corte en carga...............Qn>40kvar/440V
Main switch or circuit breaker H¡Ý700mm
Protecci¨®n diferencial / Leakage protection


Part number Qn (kvar)
440 V
Composition Steps Program Qn (kvar)
400 V
Cabinet
(H x L x P)
(kg)
Weight
(€)
Price
BATM0844050I 5 2x1.25+2.5 4x1.25 1.1.2 4.1 500x400x200 18 722
BATM0844087I 8.75 1.25+2.5+5 7x1.25 1.2.4 7.2 500x400x200 18 800
BATM0844125I 12.5 1x2.5+2x5 5x2.5 1.2.2 10.3 500x400x200 18 865
BATM0844175I 17.5 2.5+5+10 7x2.5 1.2.4 14.5 500x400x200 19 892
BATM0844200I 20 2x5+1x10 4x5 1.1.2 16.5 500x400x200 19 900
BATM0844250I 25 5+2x10 5x5 1.2.2 20.6 500x400x200 20 919
BATM0844275I 27.5 2.5+5+2x10 11x2.5 1.2.4 22.7 500x400x200 20 1.179
BATM0844312I 31.25 6.25+2x12.5 5x6.25 1.2.2 25.8 500x400x200 20 940
BATM0844350BI 35 5+3x10 7x5 1.2.2 29 500x400x200 22 1.225
BATM0844375BI 37.5 2.5+5+3x10 15x2.5 1.2.4 31 500x400x200 23 1.279
BATM0844400BI 40 5+5+3x10 8x10 1.1.2 33 500x400x200 23 1.295
BATM0844437BI 43.75 6.25+3x12.5 7x6.25 1.2.2 36 500x400x200 30 1.23
Part number Qn (kvar)
440 V
Composition Steps Program Qn (kvar)
400 V
Cabinet
(H x L x P)
(kg)
Weight
(€)
Price
BATM0844500 50 10+2x20 5x10 1.2.2 41.3 700x500x260 32 1.4
BATM0844550 55 5+10+2x20 11x5 1.2.4 45 700x500x260 35 1.47
BATM0844625 62.5 12.5+2x25 5x12.5 1.2.2 51.7 700x500x260 37 1.391
BATM0844687 68.75 6.25+12.5+2x25 11x6.25 1.2.4 56.8 700x500x260 38 1.534
BATM0844700 70 10+3x20 7x10 1.2.2 58 700x500x260 38 1.58
BATM0844750 75 5+10+3x20 15x5 1.2.4 62 700x500x260 39 1.803
BATM0844800B 80 2x10+3x20 8x10 1.1.2 66 700x500x260 39 1.86
BATM0844937 93.75 6.25+12.5+3x25 15x6.25 1.2.4 77.5 700x500x260 40 1.925
BATM08441000B 100 2x12.5+3x25 8x12.5 1.1.2 82.5 700x500x260 40 2.121
BATM08441050 105 15+3x30 7x15 1.2.2 87 700x500x260 41 2.046
BATM08441125 112.5 7.5+15+3x30 15x7.5 1.2.4 93 700x500x260 41 2.158
Part number Qn (kvar)
440 V
Composition Steps Program Qn (kvar)
400 V
Cabinet
(H x L x P)
(kg)
Weight
(€)
Price
BATM1844118I 118.75 6.25+12.5+4x25 19x6.25 1.2.4 98 800x600x260 80 2.19
BATM1844125I 125 12.5+12.5+4x25 18x12.5 1.2.4 103 800x600x260 81 2.225
BATM1844137I 137.5 12.5+5x25 11x12.5 1.2.2 114 800x600x260 83 2.25
BATM1844142I 142.5 7.5+15+4x30 19x7.5 1.2.4 118 800x600x260 84 2.275
BATM1844150I 150 15+15+4x30 10x15 1.1.2 124 800x600x260 85 2.3
BATM1844165I 165 15+5x30 11x15 1.2.2 136 800x600x260 86 2.4
BATM1844180I 180 6x30 6x30 1.1.1 149 800x600x260 87 2.5

Other ratings, voltages and frequencies available on request.

BATM080
BATM0844050I BATM0844400 BATM0844075I BATM0844437 BATM0844100I BATM0844500 BATM0844125I BATM0844550 BATM0844137I BATM0844600 BATM0844150I BATM0844625 BATM0844175I BATM0844700 BATM0844187I BATM0844750 BATM0844200I BATM0844800 BATM0844250I BATM0844800b BATM0844275I BATM0844875 BATM0844300I BATM08441000 BATM0844312I BATM08441000b BATM0844350BI BATM08441050 BATM0844375BI BATM08441125 BATM0844400BI BATM08441200 BATM0844350 BATM08441200b BATM0844375

  • µçÁ¦µçÈÝÆ÷Power capacitors

  • г²¨Â˲¨Æ÷Harmonic filters
  • µçÈÝÆ÷¹ñAutomatic Banks

  • ·µ»ØÎ÷°àÑÀLIFASAµçÈÝÆ÷Ê×Ò³
  • ·À»¤Â˲¨Æ÷Protection filters
  • ÎÞ¹¦¹¦ÂÊ¿ØÖÆÆ÷Reactive power controllers
  • ¸½¼þAccessories and auxiliary
  • µç»úºÍÕÕÃ÷µçÈÝÆ÷MOTOR AND LIGHTING CAPACITORS