Ô­FMDϵÁвúÆ·ÒÑÉý¼¶»»´úΪFMLϵÁУ¬¹úÄÚ³£ÓõÄÔ­FMD4050µÄÌæ´úÐͺÅΪFML4460£¬±¾¹«Ë¾³£±¸FML4460ÏÖ»õ£¬»¶Ó­ÓиòúÆ·ÐèÇóµÄ¿Í»§ËæʱÓëÎÒÃÇÁªÏµ¡£Í¬Ò»²úÆ·ÊÊÓÃÓÚ²»Í¬µçѹµÈ¼¶£¬Îª¿Í»§Ìṩ¸ü¶à±ãÀû£»²úÆ·³ß´çÓëÔ­À´Ïàͬ£¬±ãÓÚÓû§Ì滻ԭʹÓòúÆ·£¬ÖØÁ¿±ÈÔ­À´²úÆ·ÓÐËùϽµ£»²úÆ·ÑÕÉ«ÓÉÔ­À´µÄÀ¶É«¸Ä±äΪ»Ò°×É«£¨RAL7035£©£¬Ïêϸ²úÆ·×ÊÁÏÇëµã»÷ÕâÀïä¯ÀÀ»òÀ´ÐÅÀ´µç×Éѯ¡£µã»÷ÏÂÔزúÆ·Ñù±¾

MCA PLUS II NETWORK ANALYSER

General characteristics
¡¤ The MCA Plus II network analyser is an electronic device that allows the reading of the main advanced parameters of a supply network in the true RMS values.
¡¤ It is specially designed for its easy installation and set up, it requires the connection of four voltage terminals and three current transformers. The capacitive control keypad in the front allows to change the displayed parameters in a few seconds. The MCA Plus II have LCD backlight display for an easy reading in all light conditions.

New features


¡ñ Suitable for MV and LV installations
¡ñ 4-Quadrant measurement for consumption and generation in the same measurement point ¡ñ High IP protection (Frontal )
¡ñ 2 built-in digital outputs (S0 Interface or alarms)
¡ñ 2 built-in digital outputs by relay
¡ñ 2 built-in digital inputs (tariff selection or external alarms)
¡ñ RS-485 Modbus/RTU Communications
¡ñ Backlight touch keyboard
¡ñ Analog visualizations for instantaneous parameters (Power, MaxPower reach and Cos ¦Õ or PF)
¡ñ Backlight display
¡ñ LED Alarm indicator
Parameter III L1 L2 L3
Simple voltage phase-phase V ¡¡
Compound voltage phase-neutral V ¡¡
Current A
Activa power kW
Reactiva power kvar ¡¡
Power factor ¡¡ ¡¡
Cos ¦Õ ¡¡ ¡¡ ¡¡ ¡¡
THD(U)% ¡¡ ¡¡
THD(I)% ¡¡ ¡¡
d(U)% ¡¡ ¡¡
d(I)% ¡¡ ¡¡
Capacitive reactive power kvar C
Inductive reactive power kvar L
Apparent power kVA ¡¡ ¡¡ ¡¡
Frequency Hz ¡¡ ¡¡ ¡¡
Active energy kWh ¡¡ ¡¡ ¡¡
Capacitive reactive energy kvarh C ¡¡ ¡¡ ¡¡
Inductive reactive energy kvarh L ¡¡ ¡¡ ¡¡
Apparent energy kVAh ¡¡ ¡¡ ¡¡
Active power maximeter kW ¡¡ ¡¡ ¡¡ ¡¡
Apparent power maximeter kVA ¡¡ ¡¡ ¡¡
Current maximeter A ¡¡
Neutral current A

TeChniCal CharaCteristiCs
Power supply:
Single phase: .............................................................................................................. 85 ... 265 Vac / 95 ... 300 Vcc
Voltage tolerance :- ................................................................................. 15 % / +10 %
Frequency: ..................................................................................................................... 50 - 60 Hz
Max. consumption: ........................................................................................... 4,2 VA
Operating temperature: .................................................................... -10o C + 50 o C
Humidity (wihtout condensation): ............................................ 5% ~ 95%
Mechanical characteristics:
Box material: ........................................................................................................... Self extinguishing V0 plastic
Protection:
- Equipment assembly (front): ......................................................
- Non assembled equipment (side and rear cover): ...................................................................... IP 31
Dimensions (mm):............................................................................................................. 96 x 96 x 63
Weight: ..................................................................................................................................... 0,400 kg
Accuracy class:
Voltage: ............................................................................................................................... 0,5 % ¡À 2 digits
Current: ............................................................................................................................ 0,5 % ¡À 2 digits
Powers: ............................................................................................................................. 1 % ¡À 2 digits
Measurement conditions :
- Temperature: ........................................................................................................ + 5 oC + 45 oC
- Power factor: ............................................................................................ 0,5 ... 1
- Measurament margin (scale range) : ....................... 10..... 100 % (Current transformar not include)
Measurement circuit:
Nominal voltage phase-neutral: ................................................. Max. 300
Between phase: ........................................................................................................... Max. 520 V ac
Frequency: ..................................................................................................................... 45 ~ 65 Hz
Nominal current: .............................................................................................. In / 5 A
Permanent overload: ......................................................................... 1,1 In
Current circuit consumption: ............................................................ 0,75 VA
Transistor output features
Type: Opto.isolated transistor (open collector): ......................................................................... NPN
Maximun operating voltage: .................................................. 24 V dc
Maximun operating current: .............................................. 50 mA
Maximun frequency: ................................................................................... 5 pulsos/seg./5 pulses/sec.
Lenght of pulse: .................................................................................................. 100 ms
Communication: ....................................................................................................... RS 485
Safety:
Cat. III - 300 V ca / 520 ca
Class II double insulation against electric shock
Standards:

Part number Model Size (mm) Communication Module Voltage (V) Price (€)
MCAPLUSII New MCA Plus Advanced 96 x 96 YES 85 ... 265 Vac
95 ... 300 Vcc
275

  • µçÁ¦µçÈÝÆ÷Power capacitors

  • г²¨Â˲¨Æ÷Harmonic filters
  • µçÈÝÆ÷¹ñAutomatic Banks

  • ·µ»ØÎ÷°àÑÀLIFASAµçÈÝÆ÷Ê×Ò³
  • ·À»¤Â˲¨Æ÷Protection filters
  • ÎÞ¹¦¹¦ÂÊ¿ØÖÆÆ÷Reactive power controllers
  • ¸½¼þAccessories and auxiliary
  • µç»úºÍÕÕÃ÷µçÈÝÆ÷MOTOR AND LIGHTING CAPACITORS